CONNECTING THE LN-8 OR LN-9 TO THE
IDEALARC DC-655 (TERMINAL STRIP)

1.

Set the Idealarc DC-655 POWER toggle switch to
the OFF (0) position.

2.

Disconnect main AC input power to the Idealarc
DC-655.

3.

Connect the wire feeder control cable leads to the
Idealarc DC-655 terminal strip as shown in Figure
C.4.

4.

Connect the wire feeder control cable ground lead
to the frame terminal marked .

5.

Extend wire feeder control cable lead #21 so it can
be connected directly to the work piece.

a. Make a bolted connection using AWG #14 or

larger insulated wire. Tape the bolted connec-
tion with insulating tape.

b. An S-16586- X remote voltage sensing work

lead is available for this purpose.

c. Keep the #21 lead electrically separate from

the work cable circuit and connection.

d. Tape the #21 lead to work cable for ease of

use.

6.

Connect LN-9 wire feeder control jumpers on
Voltage Control board. See LN-9 Operator’s
Manual.

NOTE: The connection diagram shown in Figure C.4

shows the electrode connected for positive
polarity. To change polarity:

a. Set the Idealarc DC-655 POWER toggle

switch to the OFF (0) position.

b. Move the electrode cable to the negative (-)

output terminal (High inductance or low
inductance as needed).

c. Move the work cable to the positive (+) output

terminal.

d. Connect control cable lead #21 to “+21” on

the terminal strip.

7.

Set the OUTPUT CONTROL switch to the
“Remote” position and the OUTPUT TERMINALS
switch to the “Remote” position.

ACCESSORIES

C-8

C-8

IDEALARC DC-655

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

FIGURE C.4 - LN-8 OR LN-9 WIRE FEEDER CONNECTION TO THE IDEALARC DC-655

NEGATIVE

POSITIVE

32

31

2

4

GND

21

ELECTRODE CABLE

TO WIRE FEED UNIT

TO WORK

}

POWER SOURCE

N.E.

CABLE

21

A

B

C

}

TO LN-8 OR LN-9

CONTROL

INPUT CABLE PLUG

41 4 2 31 32

75 76 77

21

-

21

+

REMOTE VOLTAGE SENSING LEAD