THERMAL FAN/SNUBBER BOARD LED CHART

LED #

LED FUNCTIONS AND INDICATIONS

(Machine is ON)

1

Indicates fan should be running.

2

Indicates welding current is greater than 200 amps.

3

Indicates fan should be running due to heating of main
SCRs.

4

Indicates an open thermal fan thermistor or an open con-
nection between the thermistor and the thermal fan/snub-
ber board. See the Wiring Diagram (leads #319 and
#316).

5

Indicates a thermostat (choke or secondary) has opened.
The thermal protection light should also be illuminated.

6

Indicates the fan motor should be running. LED 6 should
be illuminated and the fan running when any
of the following LEDs are lit: LED 2, LED 3, LED 4, or
LED 5.