See the simplified, Trigger diagram, Simplified trigger diagram – Lincoln Electric IDEALARC DC-655 User Manual
Page 58: D. see the simplified trigger diagram, Troubleshooting & repair, F-16, Figure f.3 – simplified trigger diagram
Advertising
9.
Check continuity (zero ohms) from lead #41
(plug P15 pin-10) to plug J5-pin 1 at the fir-
ing board. See the Simplified Trigger
Diagram and Figure F.1. If a resistance of
any value is indicated, check the associat-
ed wires, plugs and thermostats.
TROUBLESHOOTING & REPAIR
F-16
F-16
IDEALARC DC-655
2
4
C
D
P16
2
4
TERMINAL
STRIP
42A
13
P15
5
9
41
11
10
2
#
#4
TO #41 AT MAIN
TRANSFORMER
TO #42 AT MAIN
TRANSFORMER
#273
N.C.
SECONDARY
THERMOSTAT
#41
N.C.
CHOKE LEAD
THERMOSTAT
#4
#41
9J5
1J5
11J5
10J5
#309
#310
TO
CONTROL
BOARD
OUTPUT
TERMINAL
SWITCH
14-PIN
RECEPTACLE
10AMP
CIRCUIT
BREAKER
FIRING BOARD
LATCHING
RESISTOR
ENABLE
FIRING
CIRCUIT
ENABLE
5
6
LED10
FIGURE F.3 – SIMPLIFIED TRIGGER DIAGRAM
Advertising