SEMIAUTOMATIC WIRE FEEDERS

CONNECTING THE LN-7 TO THE IDEALARC
DC-655 (14-PIN MS RECEPTACLE)

1.

Set the POWER toggle switch to the OFF (0) posi-
tion.

2.

Disconnect main AC input power to the Idealarc
DC-655.

3.

Connect the electrode cable from the control
cable to the “+” terminal of the welder and to the
LN-7 wire feeder. Connect the work cable to the
“-” terminal of the welder (High inductance or low
inductance as needed). Reverse this hookup for
negative polarity.

NOTE: Welding cable must be sized for the current

and duty cycle of the application.

4.

Connect control cable between the DC-655 and
the LN-7. See Figure C.3.

5.

Set the MODE switch to a CV (constant voltage)
position at the welder.

6.

Adjust wire feed speed at the LN-7 and set the
welding voltage with the output CONTROL.

NOTE: If optional remote control is used, place the

OUTPUT CONTROL and the OUTPUT TERMI-
NALS switch in the “Remote” position.

ACCESSORIES

C-6

C-6

IDEALARC DC-655

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

41 4 2 31 32

75 76 77

NEGATIVE

POSITIVE

32

31

2

4

GND

21

ELECTRODE CABLE

TO WIRE FEED UNIT

TO WORK

}

POWER SOURCE

LN-7 TO INPUT

CABLE PLUG

LN-7 CONTROL

CABLE

21

-

21

21

+

REMOTE VOLTAGE SENSING LEAD

FIGURE C.3

IDEALARC DC-655/LN-7 WITH K584 INPUT CABLE ASSEMBLY CONNECTION DIAGRAM