The fan runs continuously, Troubleshooting & repair, Caution – Lincoln Electric IDEALARC DC-655 User Manual

Page 51

Advertising
background image

TROUBLESHOOTING & REPAIR

F-9

F-9

IDEALARC DC-655

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Observe Safety Guidelines

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
1-800-833-9353.

PROBLEMS
(SYMPTOMS)

POSSIBLE AREAS OF
MISADJUSTMENT(S)

RECOMMENDED
COURSE OF ACTION

FUNCTION PROBLEMS

The Thermal Protection Light is on
but the fan does not run.

1. Check for obstructions that

could prevent the fan from turn-
ing.

1. The fan motor could be faulty.

Check or replace.

2. The Thermal Fan/Snubber PC

Board may be defective. See
the Thermal Fan/Snubber PC
Board LED Chart.

The fan runs continuously.

1. Note: The fan is thermal con-

trolled. Under normal condi-
tions, it does not continuously
run.

1. The Thermal Fan Thermistor

may be faulty. See the Wiring
Diagram.

2. The Thermal Fan/Snubber PC

Board may be defective. See
the Thermal Fan/Snubber PC
Board LED Chart.

One or both of the optional digital
meters are not lit.

1. Check for loose plugs P13 and

P12 at the digital meter PC
board.

1. The digital meter board may not

be receiving voltages from the
T1 transformer windings.
Perform the Main Transformer
Test.

2. Check the wiring between Plug

J13 and the associated leads at
the main transformer. See the
Wiring Diagram.

3. The digital meter PC board may

be faulty.