Operations Manual, HPA2, Compact Outdoor SSPA

The selected interface is controlled by a combination of internal SSPA settings and/or
Interface control pins: Baud1 (Pin e) and Baud0 (Pin j) on the J4 M&C connector (See Table
10-1
).

Note: The state of these pins is sensed by the SSPA unit only at power up!
Changing the state of these pins during normal unit operation will not
affect the selected type of interface.


FSK interface allows the selection of Normal and VSAT protocols.


Note: For proper FSK interface operation, the SSPA internal settings must
be selected to 9600 Baud and Normal protocol. Do not make a connection
to interface control pins Baud1 and Baud0!

Note: For maximum ESD protection of a SSPA’s Serial interface internal
circuit, the RS-232/RS-485 interface is isolated from the SSPA chassis
ground. Serial interface has a separate interface ground pin (Pin d on the
J4 connector). Connecting this pin to common ground will effectively
disable the protection circuit and may cause interface failure.

All interface lines are equipped with transient suppression devices.
Adding extra transient protection to communication lines is not required
and may cause interface failure!

Baud0 (Pin j) state Baud1 (Pin e) state

Selected interface

Open Open

Interface

selected by Internal SSPA settings

Closure to

Chassis ground

Open

Interface is forced to Ethernet interface. IP address is software
selectable. Protocol is forced to Normal (HTTP web supported)

Open

Closure to

Chassis ground

Interface is forced to Ethernet interface. IP address is fixed to
192.168.0.9. Protocol is forced to Normal (HTTP web supported)

Closure to

Chassis ground

Closure to

Chassis ground

Interfaced is forced to 9600 Baud serial.

Table 10-1: Interface Selection