Table 10-7: system settings data values – Paradise 205486 REV F User Manual

Page 115

Advertising
background image

Operations Manual, HPA2, Compact Outdoor SSPA

208495 REV C

115

Table 10-7: System Settings Data Values

Data

Address

# Bytes

Description

Limits and Byte Values

1

1

System Operation Mode

Single Amplifier = 255; 1:1 Redundant = 0; Dual 1:1 = 1

(version 3.60); Maintenance Switch =2 (version 5.05)

2

1

System Hierarchical Address

HPA 1= 0; HPA 2= 255

3

1

Unit Start Up State (in Redundancy)

Standby Amplifier = 0; On Line Amplifier = 1

4

1

Mute State

Mute Clear (Transmit Enable) = 255

Mute Set (Transmit Disable) = 0

5 1

Attenuation Level

(dB down from maximum gain)

[1 bit for every 0.1 dB]

0 dB attenuation = 0; 20 dB attenuation = 200

6

1

Module Gain Control Authority

Serial Port Gain Control = 255

External Analog Voltage Gain Control = 0

7

1

Amplifier Network Address

0 to 255

8

1

High Temperature Alarm Threshold

0 to 125 (in °C)

9

1

SSPA module Calibration Mode

Temperature Compensated = 255 (normal state)

Calibration Mode = 0

10

1

SSPA Spare Fault Status

Ignore Spare Fault = 255

Fault on value of window on ADC channel = 0 to 7

Fault on External Mute = 8

11

1

SSPA Spare Fault Handling

Minor Fault (no effect on Summary Fault) = 255

Major Fault (Triggers Summary Fault) = 0

Major Fault with Mute (Transmit Disabled) = 1

12

1

SSPA Auxiliary Fault Status

Ignore Auxiliary Fault = 255

Fault on Logic Low State = 1

Fault on Logic High State = 0

Startup in Low Z State = 2

Startup in High Z State = 3

(version 3.50 - See SierraCom Protocol for details)

13

1

SSPA Auxiliary Fault Handling

Minor Fault (No effect on Summary) = 255

Major Fault (Triggers Summary Fault) = 0

Major Fault with Mute (Transmit Disabled) =1

Minor Fault with Mute = 2 (version 3.50)

14

1

Block Up Converter Fault Status

Ignore BUC Fault = 255

Fault on Logic Low State = 1

Fault on Logic High State = 0

15

1

Block Up Converter Fault Handling

Minor Fault (no effect on Summary Fault) = 255

Major Fault (Triggers Summary Fault) =0

Major Fault with Mute (Transmit Disabled) = 1

16

1

Protocol Select

Normal Protocol = 255

VSAT Legacy Protocol = 2 (version 3.50; compatible with

SierraCom VSAT BUC and NDSat SkyWAN modem)

IPNet (Ethernet UDP + Web M&C) = 2;

SNMP V1 = 3

17

1

Baud Rate Select

9600 = 255; 38400 = 0; 19200 = 1; 4800 = 2; 2400 = 3

18-19

2

Reserved

Reserved for Factory use.

20

1

Standby Mode

Hot standby=255; Cold standby=0 (version 3.50)

21

1

BUC Reference

Autoswitch = 0; External = 1; Internal = 2 (version 3.60)

(continued)

Note: Data length must be at least two bytes to form integer with the lower byte sent first. If an odd number of bytes is received, the last byte
will be saved as the lower byte of the integer and the upper part will be zero.