At first it may be thought that a 10 MHz signal could be injected into the normally terminated
port of the input switches. While in a normal operating state with all three BUCs operational
this would work fine. However in the event of a failure of one of the on-line units, the 10 MHz
would also be interrupted to the standby unit, as shown in Figure 8-25. Due to the quick
determination of a unit fault, the controller will interpret a fault on the standby amplifier and
reliable switchover can not be guaranteed.

To overcome the problems that result from interruption of the 10 MHz reference, it is
imperative that the reference be injected in the system after the waveguide switches. One
technique could be to install a multiplexer on the input of each amplifier that would allow the
injection of the 10MHz reference. In this case a separate 10 MHz line would have to be run to
the system and a three way splitter could distribute the reference to each amplifier.

The standard Teledyne Paradise Datacom configuration overcomes this issue by using a
Reference Combiner assembly.

RF OUT-POL 2

RF OUT-POL 1

Amp 1

Amp 2

Amp 3

RCP2-1200

Redundant Controller

BUC

L Band Input- POL 1

L Band Input- POL 2

BUC

BUC

Alarm

Inputs

Switch Drive

10MHz

10MHz

10 MHz, Standby

During Switch-Over, 10MHz is interrupted to Standby BUC

Figure 8-25: 1:2 Redundant System with (3) 10MHz inputs through the input

switches. This arrangement allows for unreliable switch-over due to 10 MHz

interruption to standby unit