Paradise 205486 REV F User Manual

Page 28

Advertising
background image

28

208495 REV C

Operations Manual, HPA2, Compact Outdoor SSPA

3.0.2 Legacy Compact Outdoor SSPAs

Compact Outdoor SSPAs with serial numbers of less than 300,000 did not include isolated
grounds for RS-232/RS-485 serial communications. The remote communication connections
are slightly different and outlined in Figures 3-4 and 3-5.

Figure 3-2: J4 Connections for RS-485 Communications

Chassis Ground

TX Enable

Baud Select 0

Baud Select 1

RS232/RS485 Select

Isolated Return for RS232/RS485

RS485 (RX-) RS232 (RX)

RS485 (TX-) RS232 (TX)

RS485 (TX+)

RS485 (RX+)

V

B

j

e

D

d

F

E

T

U

J4

Figure 3-3: J4 Connections for RS-232 Communications

Chassis Ground

TX Enable

Baud Select 0

Baud Select 1

RS232/RS485 Select

Isolated Return for RS232/RS485

RS232 (RX)

RS232 (TX)

V

B

j

e

D

d

F

E

J4

Figure 3-4: J4 Connections for RS-485 Communications for Serial Numbers <300,000

Chassis Ground

TX Enable

RS232/RS485 Select

Baud Select 0

Baud Select 1

Chassis Ground

RS485 (RX-) RS232 (RX)

RS485 (TX-) RS232 (TX)

RS485 (TX+)

RS485 (RX+)

9600 BAUD Selection shown

V

B

D

j

e

d

F

E

T

U

J4

Advertising