Operations Manual, HPA2, Compact Outdoor SSPA

8.1.2.2 PC Control using RS232 and Paradise M&C Software

In applications requiring remote monitor and control of the redundant system, the Teledyne
Paradise Datacom Universal M&C program has a control panel that can be used for this
purpose. To enable the 1:1 system to operate with the remote control software, first configure
each amplifier for 1:1 redundant operation as previously described in the Stand-Alone 1:1
Redundant System section.

When using RS232, a separate COM port will be required for each amplifier. Therefore a
computer with at least two COM ports is required for such a system. Systems using RS232
are limited by the length of the communication cable from the amplifiers to the computer. This
is typically a maximum of 30 ft. (9 m) for most RS-232 device drivers. Systems requiring
longer communication cable links should use RS-485 communication.

After starting the M&C program, select [Action] → [Add Unit] → [Compact Outdoor SSPA].
See Figure 8-8. The Add New SSPA window will appear as shown in Figure 8-9.

Figure 8-8: Adding a SSPA Monitor and Control Window