208495 REV C

Operations Manual, HPA2, Compact Outdoor SSPA

3.1 Port J4 Pin-Outs


Table 3-1 shows the pin-outs for the J4 Monitor & Control Connector for Ethernet capable
units.

Table 3-1: Monitor & Control Connector (J4) Pin-Out (Ethernet capable)

Signal

Type

Function

Pin

Notes

Mute Input

Closure to Ground

Disables DC Power to SSPA

B

Unit powers up muted;

This line must be pulled to ground

(V) to enable amplifier

Auxiliary Input

Closure to Ground

Auxiliary Input

P

Summary Alarm

Form C Relay

Closed on Fault

Common

Open on Fault

L
a
b

L-a : normally open

a-b : normally closed

Auxiliary Alarm

Form C Relay

Closed on Fault

Common

Open on Fault

N

Z

M

N-Z : normally open

Z-M: normally closed

Low RF Fault Output

Open Collector

High on Fault

G

Requires external pull-up

10 Base-T TX-

W

10 Base-T RX-

H

10 Base-T RX+

J

10 Base-T TX+

X

Spare Input

Analog Input

S

+5V max.

RF Power Detector

Analog Output

Relative Indication

of RF Output Power

R

+4.0 VDC at Psat

Gain Adjust Input

Analog Input

Adjusts Amplifier Gain

over 20dB range

A

2.5 vdc = Max Gain 75dB

0.5 vdc = Min Gain 55dB

Block Up Converter

Alarm

Open Collector

High on Fault

f

Requires external pull-up

RS232 / RS485

Select

Closure to Ground Selects Serial Communication

D

Default is RS 485; pull to ground (d)

to enable RS 232

RS 485 TX-

or RS232 OUT

Serial TX Output

Serial Link Data Port

E

Refer to M&C section

RS 485 RX-

or RS232 IN

Serial RX Input

Serial Link Data Port

F

RS 485 TX+

Serial TX Output

Serial Link Data Port

T

RS 485 RX+

Serial RX Input

Serial Link Data Port

U

GND

Signal Ground

Common Signal Return

V

Chassis ground

GND

Signal Ground

Isolated Comm Ground

d

Ground for Signals D, E, & F

Baud Select 0

Closure to Gnd

Select Baud Rate & Protocol

j

Refer to Section 11

Baud Select 1

Closure to Gnd

Select Baud Rate & Protocol

e

Refer to Section 11

PGM Switch

Flash Firmware Port

g

Reserved for Programming

PGM CLK

Flash Firmware Port

c

Reserved for Programming

PGM-Sout

Flash Firmware Port

K

Reserved for Programming

PGM-Sin

Flash Firmware Port

Y

Reserved for Programming

PGM +5V

Flash Firmware Port

h

Reserved for Programming

PGM Enable

Flash Firmware Port

C

Reserved for Programming

Refer to M&C section