Paradise 205486 REV F User Manual

Page 89

Advertising
background image

Operations Manual, HPA2, Compact Outdoor SSPA

208495 REV C

89

A special case of the 1:2 Redundant System exists when an external reference is
required of the system. With an external 10 MHz reference input on each polarity input to the
system, the standby amplifier will not receive a reference signal and therefore would be in a
faulted condition. In this state, the redundant controller will not allow the standby amplifier to
come on line if a failure occurs with amplifier #1 or amplifier #3. See Figure 8-24.

RF OUT-POL 2

RF OUT-POL 1

Amp 1

Amp 2

Amp 3

RCP2-1200

Redundant Controller

BUC

L Band Input- POL 1

L Band Input- POL 2

BUC

BUC

Alarm

Inputs

Switch Drive

10MHz

10MHz

No path for 10MHz to

the Standby BUC

Figure 8-24: 1:2 Redundant System with External Reference showing the

absence of 10 MHz reference to the stand-by BUC