Operations Manual, HPA2, Compact Outdoor SSPA

208495 REV C

43

[

14

]

Fault Setups: The user may also adjust the Spare, Auxiliary, BUC, and

Forward RF Fault Status and Handling via the appropriate pull-down menus on
the Settings Window.

Spare/Auxiliary/BUC/Forward RF Fault Handling: Selects whether the
associated fault should be a major or minor fault, and whether the fault
should mute the unit. A minor fault will trigger a Spare/Auxiliary/BUC/
Forward RF Fault alarm but not trigger a Summary Fault. A major fault
will trigger both an Spare/Auxiliary/BUC/Forward RF Fault and a
Summary Fault.
Auxiliary/BUC Fault Status: Determines if the associated fault input
should be ignored or enabled (either Logic High or Logic Low; or Logic Z-
State for Auxiliary Fault).

Forward RF Threshold: Allows the user to assign the threshold at which
a Forward RF Fault will be triggered.

3.4.3 IP Setup Window

If the user wishes to set up the networked Compact Outdoor SSPA with custom IP settings,
the internal IP settings need to be modified. Click on the IP Setup Tab. See Figure 3-15.

The SSPA will use the default settings until the unit is reset by removing its AC
power. Unplug the Quick Start cable from the M&C connector. (If the unit is
restarted with the Quick Start cable connected, it will always come up with
default IP settings
). Apply power to the SSPA. Re-plug the Quick Start cable
into J4, and check connectivity with the custom IP settings.

Make sure that the Protocol setting in the Settings tab of the Universal M&C is
set to IPNet, as shown in Figure 3-13.

If custom IP settings will be used in normal operation, the user will need to con-
struct an IP cable or modify the Quick Start Cable by disconnecting the interface
control pins (pins j and e, Baud Select 0 and Baud Select 1) from ground. In this
configuration, the SSPA will always use the saved communication control set-
tings rather than the default configuration.

Figure 3-15: Universal M&C, IP Setup

Click

“Change IP Settings”

Modify IP Settings

to work with your network.