5 typical system configuration, 6 ifl cable considerations – Paradise 205486 REV F User Manual

Page 55

Advertising
background image

Operations Manual, HPA2, Compact Outdoor SSPA

208495 REV C

55

4.5 Typical System Configuration


This section shows the Compact Outdoor SSPB in a common system application. Figure
4-3
shows the Compact Outdoor used with a Teledyne Paradise Datacom Evolution Series
PD25 modem.

4.6 IFL Cable Considerations


Consideration should be given to using a high quality IFL between the indoor equipment and
Compact Outdoor SSPB. The system designer must always consider the total cable loss for a
given length and also the implications of the slope of attenuation across the 950 to 1450 MHz
bandwidth. Table 4-3 gives the approximate attenuation vs. frequency for a variety of cable
types.

It is recommended to use a quality grade of 50 ohm cable such as Belden 9913, 9914, or
7733. Check the manufacturer’s technical data to make sure that the insulation is sufficient for
the particular installation including the cable’s temperature range. Also make sure the coaxial
connector from the IFL cable to the Compact Outdoor input is wrapped with a weather sealing
tape to prevent water intrusion into the coaxial cable.

PARADISE
DATACOM

IFL Cable

Indoor

Equipment

Outdoor

Equipment

IF: 950 - 1450 MHz (-30 to -20 dBm ) at Compact Outdoor SSPB

Ref: 10 MHz (-5 dBm to +5 dBm) at Compact Outdoor SSPB

Figure 4-3: Compact Outdoor SSPB with PD25 Evolution Modem

RS485 M&C

Cable Type

Center

Conductor DC

Resistance per

1000 ft.

Outer

Diameter

(inches)

Attenuation at

950 MHz

dB per 100 ft.

Attenuation at

1450 MHz

dB per 100 ft.

Slope across

band for 100

ft. cable (dB)

Slope across

band for 300

ft. cable (dB)

RG-214

1.7

.425

7.8

11.3

3.5

10.5

Belden 8214

1.2

.403

6.8

9.2

2.4

7.2

Belden 7733

.9

.355

5.8

8.3

2.5

7.5

Belden 9914

1.2

.403

4.5

6.3

1.8

5.4

Belden 9913

.9

.403

4.2

5.6

1.4

4.2

Table 4-3: Common Coaxial Cable Characteristics

Advertising