Paradise 205486 REV F User Manual

Page 114

Advertising
background image

114

208495 REV C

Operations Manual, HPA2, Compact Outdoor SSPA

10.1.5 Serial Communications Protocol

Tables 10-5 through 10-9 describe the various values of the serial communications protocol.

Byte position

Byte Value (Hex)

Description

1

0xAA

Frame Sync 1

2

0x55

Frame Sync 2

3 Destination

Address

-//-

4

Source Address

-//-

5

Protocol Version

Protocol compatibility hole, must be set to 0

6

Request ID

Service Byte

7

Command

0, Set Request; 1, Get Request

8

Data Tag

0, System Settings (see Table 10-7); 1, System Thresholds (see
Table 10-8); 2, Temperature Sensor Settings; 3, System Condi-
tions (see Table 10-9); 4, ADC Data (reserved for factory use)

9

Data Address

Setting number, Sensor command, EEPROM address

10

Data Length

Total length of the data, valid values 1-30

11+N Data

Actual

Data

11+N+1

Checksum

Dest. Address + Source Address + Protocol Version + Request ID
+ Command + Data Tag + Data Address + Data Length + Data

Table 10-5: Request Frame Structure

Byte position

Byte Value (Hex)

Description

1

0xAA

Frame Sync 1

2

0x55

Frame Sync 2

3 Destination

Address

-//-

4

Source Address

-//-

5

Protocol Version

Protocol compatibility hole, must be set to 0

6

Request ID

Service Byte

7

Command

2, Set Response; 3, Get Response

8

Data Tag

0, System Settings (see Table 10-7); 1, System Thresholds (see
Table 10-8); 2, Temperature Sensor Settings; 3, System Condi-
tions (see Table 10-9); 4, ADC Data (reserved for factory use);
5, Raw NVRAM/RAM Data (reserved for factory use)

9 Error

Status

0, No Errors; 1, Too Big; 2, No Such Data; 3, Bad Value; 4, Read
Only; 5, Bad Checksum; 6, Unrecognized Error

10

Data Length

Total length of the data, valid values 1-30

11+N Data

Actual

Data

11+N+1

Checksum

Dest. Address + Source Address + Protocol Version + Request ID
+ Command + Data Tag + Data Address + Data Length + Data

Table 10-6: Response Frame Structure

Advertising