Paradise 205486 REV F User Manual

Page 31

Advertising
background image

Operations Manual, HPA2, Compact Outdoor SSPA

208495 REV C

31

Table 3-2 shows the pin-outs for the J4 Monitor & Control Connector for units that cannot
communicate via Ethernet (units with serial numbers prior to 300,000).

Signal

Type

Function

Pin

Notes

Mute Input

Closure to Ground

Disables DC Power to SSPA

B

Unit powers up muted,

This line must be pulled to ground

(V or d) to enable amplifier

Auxiliary Input

Closure to Ground

Auxiliary Fault Input

P

Summary Alarm

Form C Relay

Closed on Fault

Common

Open on Fault

L
a
b

L-a : normally open

a-b : normally closed

Auxiliary Alarm

Form C Relay

Closed on Fault

Common

Open on Fault

N

Z

M

N-Z : normally open

Z-M: normally closed

Open Collector

High on Fault

W

Reserved

Auxiliary Alarm

Open Collector

High on Fault

G

Requires external pull-up

Voltage Alarm

Open Collector

High on Fault

H

Requires external pull-up

Current Alarm

Open Collector

High on Fault

J

Requires external pull-up

Temperature Alarm

Open Collector

High on Fault

X

Requires external pull-up

Spare Fault

Open Collector

High on Fault

S

Requires external pull-up

RF Power Detector

Analog Output

Relative Indication of RF Output

Power

R

+4.0 vdc at Psat

Gain Adjust Input

Analog Input

Adjusts Amplifier Gain over 20dB

range

A

2.5 vdc = Max Gain 75dB

0.5 vdc = Min Gain 55dB

Block Up Converter

Alarm

Open Collector

High on Fault

f

Requires external pull-up

RS232 / RS485

Select

Closure to Ground

Selects Serial Communication

D

Default is RS 485; pull to ground (V)

to enable RS 232

RS 485 TX- or

RS232 OUT

Serial TX Output

Serial Link Data Port

E

RS 485 RX- or

RS232 IN

Serial RX Input

Serial Link Data Port

F

9600 default Baud Rate

RS 485 TX+

Serial TX Output

Serial Link Data Port

T

RS 485 RX+

Serial RX Input

Serial Link Data Port

U

GND

Signal Ground

Common Signal Return

V, d

Baud Select 0

Closure to Gnd

Select Baud Rate & Protocol

j

Refer to Section 11

Baud Select 1

Closure to Gnd

Select Baud Rate & Protocol

e

Refer to Section 11

PGM Switch

Flash Firmware Port

g

Reserved for Programming

PGM CLK

Flash Firmware Port

c

Reserved for Programming

PGM-Sout

Flash Firmware Port

K

Reserved for Programming

PGM-Sin

Flash Firmware Port

Y

Reserved for Programming

PGM +5V

Flash Firmware Port

h

Reserved for Programming

PGM Enable

Flash Firmware Port

C

Reserved for Programming

Table 3-2: Monitor & Control Connector (J4) Pin-Out (Non-Ethernet)