208495 REV C

Operations Manual, HPA2, Compact Outdoor SSPA

10.1.6 Serial Communication Examples

The following shows an example of a communication exchange between a PC and Compact
Outdoor Amplifier, assuming the following:

SSPA Network Address = 5

Host Computer Network Address = 10

Request ID = 0x6F


The Host PC Request String is: (refer to Table 10-5)

Byte Position Byte Value (Hex) Description

1

AA

Frame Sync Byte 1

2

55

Frame Sync Byte 2

3

5

Destination Address of Compact Outdoor SSPA

4

A

Source Address of PC sending Request String

5

0

Protocol Version Compatibility Field must always be 0

6

6F

Request ID byte is set by originator, will be echoed back by respondent

7

1

Command field for “Get” type request

8

0

“SSPA Settings” tag indicates which data from respondent is required in
response frame

9

1

Data Address field indicates the beginning data address inside of the
“SSPA Settings” data set to 1 (first element)

10

A

Data Length field indicates how many data bytes of the “SSPA Settings”
requested from the amplifier

11 8A

Arithmetic

checksum

of bytes number 3 through 10