Nortel Networks NN43001-314 User Manual

Page 320

Advertising
background image

320

Emergency Services configuration

ESA uses a route number rather than ESN route list index. However,
ESN is required at the Branch Office.

4

Configure Emergency Services Access (ESA) in LD 24.

Configure an ACD number as an Emergency Services Directory
Number.

LD 24 Configure Emergency Services Access.

Prompt

Response

Description

REQ

NEW CHG

Add new data, or change existing data.

TYPE

ESA

Emergency Services Access data block

CUST

xx

Customer number as defined in LD 15

ESDN

xxxx

Emergency Services DN (for example, 911). Up to four digits
are accepted.

ESRT

ESA route number

0-511

Range for Large System and CS 1000E system

0-127

Range for Small System and Media Gateway 1000B

DDGT

x

x

Directing Digits (for example, 1, 11, or 911). Up to four digits
are accepted.

DFCL

x

x

Default ESA Calling Number. The input must be the following
lengths:

On a system that is not FNP equipped, 8 or 11 digits are
accepted if the first digit of the input is "1"; otherwise the
input must be 7 or 10 digits.

On a system that is FNP equipped, up to 16 digits are
allowed.

OSDN

x

x

On-Site Notification station DN. The input must be a valid
single appearance internal DN.

5

Configure the Branch Office zone on the main office.

a. Configure the Branch Office zone’s ESA dialing information in

LD 117.

LD 117 Configure Branch Office zone ESA route.

Command

Description

CHG ZESA <Zone><ESA Route #><AC><ESA Prefix><ESA Locator>

Defines the ESA parameters for the Branch Office zone, where:

Zone = Zone number for the Branch Office.

Nortel Communication Server 1000

Branch Office Installation and Commissioning

NN43001-314

01.02

Standard

Release 5.0

20 June 2007

Copyright © 2007, Nortel Networks

.

Advertising