Omega Vehicle Security OMP-MODL User Manual

Page 153

Advertising
background image

10... H

YPER

T

RACK

™ R

EAL

-T

IME

D

ATA

D

ISPLAY

U

SING THE

OMP-MODL

10-4

Program Net that contains the desired Probe Point icons.
The OMP-MODL may be in either the Enabled or
Stopped mode.

2. From the HyperComm Window, click and drag the

Program Net icon on the OMP-MODL to the PC and
release it. The Program Net and Probe Point icon
information will be automatically downloaded to the PC
and a Probe Point icon will display overlaying the image
of the PC.
NOTE: If the Probe Point icon does not
display on the PC, then the transferred Program Net
does not contain Probe Point icon(s) and this Program
Net can not be used for tracking. (In this case, develop a
new Program Net containing Probe Point icons and
upload it to the OMP-MODL.)

1. From within the HyperComm Window, click on the

HyperTrack button (or double click on the Probe Point
icon overlaying the PC) and the HyperTrack window will
appear with Probe Point icon(s) displayed on the left
edge of the workspace (Figure 10... -5). These icons
represent the Probe Point icons detected in the Program
Net that was just downloaded to the PC (and which is

currently programmed in the OMP-MODL’s memory).

2. Once this Probe Point icon information is displayed on

the workspace, it can be saved to a HyperTrack Net file
(the filename extension *.PRB will be appended) by
using the File/Save As drop-down menu selection. This
file can then be used as a starting point for development
of additional nets based on the same Program Net.

Figure 10... -5: Probe Points detected in the currently loaded Net Program

Advertising