Omega Vehicle Security OMP-MODL User Manual

Page 262

Advertising
background image

11.. . A

PPENDIX

A: M

ASTER

I

CON

F

ILE

R

EFERENCE

U

SING

T

HE

OMP-MODL

11-100

R

EMOTE

C

ONTROL

F

UNCTION

I

CON

FUNCTION:

The Remote Control icon has a logic output that can be controlled real-time by the user.
This output can be connected to the logic input of any other icon.

INPUTS:

Update Clock: Output is updated to the last user selected state upon each Update

clock pulse. For example, it the connected Update clock is set for 60 sec.,
and the output state is changed by the user via HyperWare(described
below), the actual state of the output will not update until the icon receives
an Update pulse which may be up to 60 seconds later.

OUTPUTS:

Output Signal:

Logic type. The Remote Control icon updates its output after

receiving a user generated command to do so from HyperWare.

For example, the portion of a net program depicted above shows posible uses for the
Remote Control icon.The Remote Control icons labeled “Relay #1” and “Relay #2” are
connected to the logger’s relay output icons. This would enable the user to control the
state of the logger’s hardware relay outputs real-time. The Remote Control icon labled
“Log T-In” is connected to the Enable input on a Thermocouple icon which is set to log
data to memory. Whenever the Thermocouple’s enable input is ON, the channel will
sample. Conversely, if its Enable input is OFF, it will not sample. This setup allows the
user to turn on different portions of a net program at will