Probe point – Omega Vehicle Security OMP-MODL User Manual

Page 202

Advertising
background image

11.. . A

PPENDIX

A: M

ASTER

I

CON

F

ILE

R

EFERENCE

U

SING

T

HE

OMP-MODL

11-40

PROBE POINT

O

UTPUT

I

CON

FUNCTION:

Probe Point Icons mark and provide access to nodes within a Program Net for:

1. The OMP-MODL front panel display while the Net is

executing. Values at the nodes can be accessed through the
Display Probe Icon Values LCD menu selection

2. Use during real-time HyperTrack sessions. Nodes marked

with Probe Point icons are accessible via the serial link.

The units displayed by a Probe Point icon is inherited from the output to which it is
connected. These units will appear on the LCD display as well as when the Probe Point is
used in a HyperTrack Net.

INPUTS:

Data/Logic Signal: Data or Logic type. The terminal will accept either signal type.

Update Clock:

None

Enable:

Processing of icon is allowed when Enable pin is unconnected or

when connected and Enable signal is TRUE.

OUTPUTS:

Output Signal:

Hardware output (to LCD display and/or serial link ) only. No

output terminal shown on icon for Program Net connections.

ICON CONFIGURATION DIALOG BOX:

CONFIGURATION OPTIONS:

Icon Name:

Specify the label for the icon. This name will show directly under

the icon within the Program Net.

Input Name:

In this box, HyperNet displays the Output Name of the icon

connected to this icon’s Input. The Output Name can be changed in the
other icon’s dialog.

Data Output Format: The User can specify the data format that will be used in Output

of the signal. In certain applications, additional processing speed may
be realized through a judicious selection of the format.

Default to Input Formats - the default format. The data will be output
using the same data format (Floating Point or Long Integer) as the Inputs
use. This selection can be used consistently with good speed performance
and no loss of precision.