Omega Vehicle Security OMP-MODL User Manual

Page 80

Advertising
background image

3... I

NTERFACE

M

ODULES

U

SING

T

HE

OMP-MODL

3-56

Plug a telephone cord equipped with a 6/2 modular phone plug (RJ-12 type)
into the modular phone socket accessible at the end of the module (Figure
3... -36). Insure that the phone conductors are installed into the center two
locations of the plug (polarity is not critical).

Various length phone extension cords with the RJ-12 type modular phone
plugs on each end are readily available from most phone supply stores.
Insure that the `telephone base’ type cord is used... not the `handset’ cord as
the handset plug is smaller and will not effect a good connection.

Plug the other end of the phone cord into the telephone wall jack.

Hardware Configuration Switches:

No hardware configuration switches are provided on the MLIM-5-2400. All
configuration is done via the HyperWare software.

Operation of the MLIM-5-2400:

The presence of the installed MLIM-5-2400 is detected automatically by the
OMP-MODL upon power-up. If the OMP-MODL is equipped with a ML-DISP
display module, detection and initialization of the MLIM-5-2400 can be
observed on the LCD.

In loggers so equipped, at power-up, a Modem Baud Rate Test... message
will display indicating that the logger has detected the presence of the MLIM-
5 card and is testing it for modem presence. After a short wait, the display
will indicate that a 2400 Baud modem has been detected.

The MLIM-5-2400 is self-configuring with the exception of one parameter...
the number of rings before the OMP-MODL answers an incoming call. This
parameter is set from within HyperNet (the Global icon) and is thoroughly
explained within the Master Icon Listing in Appendix A under the Global icon
section.

Additional information on the setup and configuration of the modem located
at the PC is provided in Appendix K.

Advertising