Port (1 to 6) and Channel (A to D) where the actual Interface Module
channel is installed will be used for the name.

Output Name:

Specify a name for the Output signal from this icon. This Output

Name will be referenced by other icons downstream in the Program Net.

Units:

Provides a text box for User entry of a units label that will be shown at the
output from this icon. Conversion to other units can be performed within a
Program Net by adding a Math Icon onto this icon’s output.

Event / Counter / Frequency

Select COUNTER for the Counter function.

Debounce: Enables a hardware filter circuit that prevents short duration transitions

from passing into the icon. Debounce can be used to filter out contact
bounce from mechanical switches. The MLIM-2 Debounce has a time
constant of approximately 50mS. Note that the use of Debounce will delay
the actual input to output transition time by 50 to 200 mS.

FYI: Contact bounce is a phenomenon that
occurs when a mechanical switch opens or
closes. During switching, the physical electrical
contacts inside the switch bounce against each
other a number of times before they settle to
their final state.

Depending on the duty cycle of the contact
bounce, the OMP-MODL may count these
bounces as events or transitions (count mode)
resulting in technically accurate but undesired
data. By enabling the debounce function, typical
short duration contact bounce will be filtered out.

Count Rising / Falling edges: Specify which edge of the input signal is to be used to

increment the counter (eg when a device being monitored turns ON or
OFF).