Event input signal connections – Omega Vehicle Security OMP-MODL User Manual

Page 73

Advertising
background image

3... I

NTERFACE

M

ODULES

U

SING THE

OMP-MODL

3-49

Event Input Signal Connections:

To utilize an MLIM-8 channel as an Event input, connect the input signal
positive lead to an Input terminal (Chan A, B, C, D, E, F, G, or H) and the

A

B

COM

C

D

COM

E

COM

COM

F

G

H

V+

R1

Debounce RC

Current Limited Output Driver

Event Signal

Software Controlled
Debounce Circuit

Logger
Circuit Ground

HLIM-8 Terminal Strip Connections

ML135

Figure 3... -32: Simplified schematic of MLIM-8 input/output channel

(single channel shown)

12

VDC

Lamp

TTL or CMOS

Isolation from Relay contact closure

Contact Closure

15VDC Max

Channel A

Channel B

Channel C

Channel D

Common Common

ML058

Contact Closure Application

Powered Signal Application

1

2

3

4

5

6

7

Figure 3... -33: Contact closure and Powered type Event signal input

Advertising