Part III: iii

Part III: Oil in Water

Teledyne Analytical Instruments

4.1.5

Sample Delivery System........................................ 1-20

4.1.6

Safe Vent (Drainage) .............................................. 1-21

5.0 System Start-up/Calibration ........................................... 1-22
5.1 Installation Check .......................................................... 1-22
5.2 Electronics Check .......................................................... 1-22
5.3 Electrical Check ............................................................. 1-22
5.4 Sample Delivery Check ................................................. 1-23
5.5 Preparation for Calibration ............................................. 1-23

5.5.1

Required Calibration Equipment ........................... 1-24

5.5.2

Acquisition of Representative Oil Sample .............. 1-25

5.5.3

Acquisition of Representative Sample Water ............ 1-25

5.5.4

Oscilloscope Display of the I to E Converter Output .. 1-25

5.5.5

Background Signal Level Determination ............... 1-26

5.5.6

Balancing of the Optics for Equal Light Transmission with

Zero Fluid in the Sample Cell ................................. 1-27

5.6 Calibration Fluid Preparation ......................................... 1-29

5.6.1

Zero Fluid Preparation ............................................ 1-29

5.6.2

Span Fluid Preparation .......................................... 1-29

5.6.3

Calibration ............................................................. 1-30

5.6.4

Calibration by Correlation with Laboratory Analysis1-32

5.6.5

Calibration of Homogenizer ................................... 1-33

5.7 System Set-Up for Automatic Operation......................... 1-35

5.7.1

Set-Up for Automatic Sampling ................................ 1-35

5.7.2

Electronics Set-Up for Automatic Operation.............. 1-35

6.0 Automatic Operation and Routine Operational Duties ... 1-36
6.1 System Visual Check and Response Procedure ........... 1-36
6.2 Routine Maintenance ..................................................... 1-36
6.3 Suggested Preventive Maintenance Schedule .............. 1-37

7.0 Service Procedures and Adjustments ............................ 1-38
7.1 Set-Up of the Signal Processing Front End Amplifier ..... 1-39
7.2 Set-Up of the I to E Converter ........................................ 1-39
7.3 Set-Up of the Logarithmic Amplifier ............................... 1-40
7.4 The Inverting Amplifier ................................................... 1-40
7.5 The Integrated Reference and Measuring Signals ......... 1-41
7.6 Sample Cell Maintenance .............................................. 1-41
7.7 Sample System Maintenance ........................................ 1-42
7.8 Zero Filter Replacement ................................................ 1-42
7.9 316SS Zero Filter Cleaning Procedure ......................... 1-43
7.10 Lamp Replacement ........................................................ 1-44

Advertising