Trimble Outdoors SK8 User Manual

Page 102

Advertising
background image

A-38

Lassen-SK8 Embedded GPS Module

Trimble Standard Interface Protocol

*

Note – See the associated superpacket output, described later in this appendix. Packet
8E must be used to specify which superpacket is to be output.

*

Note – Automatic output of 5 A messages is supported in the Lassen-SK8 for backwards
compatibility with older TSIP applications.

Byte

Parameter
Name

Bit
Position

Default
Bit
Value

Option

Associated
Packet

2

timing

0

0

time type
0: GPS time
1: UTC

0x42, 0x43,
0x4A, 0x83,
0x84, 0x56,
0x8F-17,
0x8F-18

1

0

reserved

2

0

reserved

3

0

reserved

4

0

reserved

5-7

0

not used

3

Auxiliary PR
meas.

0

0: off

0x5A

1

0: raw

0: raw PR’s in 5A
1: filtered PR’s in 5A

0x5A

2

reserved

3

0: off
1: on

output dBHz instead of
AMU

0x5A, 0x5C,
0x47,
0x6F

4-7

reserved

Table A-38.

Command Packets 0x55 and 0x35 Data Descriptions
(Continued)

Advertising