Trimble Outdoors SK8 User Manual
Page 102
A-38
Lassen-SK8 Embedded GPS Module
Trimble Standard Interface Protocol
*
Note – See the associated superpacket output, described later in this appendix. Packet
8E must be used to specify which superpacket is to be output.
*
Note – Automatic output of 5 A messages is supported in the Lassen-SK8 for backwards
compatibility with older TSIP applications.
Byte
Parameter
Name
Bit
Position
Default
Bit
Value
Option
Associated
Packet
2
timing
0
0
time type
0: GPS time
1: UTC
0x42, 0x43,
0x4A, 0x83,
0x84, 0x56,
0x8F-17,
0x8F-18
1
0
reserved
2
0
reserved
3
0
reserved
4
0
reserved
5-7
0
not used
3
Auxiliary PR
meas.
0
0: off
0x5A
1
0: raw
0: raw PR’s in 5A
1: filtered PR’s in 5A
0x5A
2
reserved
3
0: off
1: on
output dBHz instead of
AMU
0x5A, 0x5C,
0x47,
0x6F
4-7
reserved
Table A-38.
Command Packets 0x55 and 0x35 Data Descriptions
(Continued)