3-4

Lassen-SK8 Embedded GPS Module

Software Interface

Configuring the ACE GPS receiver output protocol from TSIP to TAIP
protocol.

TSIP command packet 0xBC can be configured in accordance with the following
procedure:

1.

Run

TSIPCHAT

-Cx (Where x = Host Computer COM Port).

2.

Once TSIPCHAT is running:

a.

Press [?]. The following will be displayed:

Keystroke Command List

3.

Initiate the 0xBC Command Packet. Refer to Packet BC in the Appendix A,
Trimble Standard Interface Protocol for further information.

a.

Press [U]

b.

Press the [SPACE{BAR] to cycle through the options. Enter the following:

c.

Set (1)

d.

Press [Enter]

4.

Select the Port to be configured: Do the following:

a.

Press the [SPACE{BAR] to cycle through the options

b.

Select Port 1 (0)

c.

Press [Enter]

5.

Set the Receiver Port configuration Input Baud rate:

a.

Press the [SPACE{BAR] to cycle through the options

b.

Make a selection

c.

Press [Enter]

6.

Set the Receiver Port configuration Output Baud Rate:

a.

Cycle through the options by pressing the [SPACE{BAR]

b.

Select the Output Baud Rate

c.

Press [Enter]

7.

Set the Data Bits.

a.

Select the appropriate Data Bits. TAIP is the default: TAIP =8.

b.

Press [Enter]

8.

Set Parity.

a.

Select the appropriate Parity. TAIP is the default: TAIP =Odd.

b.

Press[Enter]

9.

Set Stop Bits.X

a.

Select the appropriate Stop Bits. TAIP is the default: TAIP =8:

b.

Press [Enter]