C.21 tm time/date – Trimble Outdoors SK8 User Manual

Page 171

Advertising
background image

Lassen-SK8 Embedded GPS Module

C-25

Trimble ASCII Interface Protocol (TAIP)

C.21

TM Time/Date

Data String Format:

AABBCCDDDEEFFGGGGHHIJJKLLLLL

Table C-25.

TM Time/Data Data String Descriptions

This message outputs the time and date as computed by the GPS sensor. The time is most
accurate when the unit is doing fixes. It is less accurate but still usable when the unit is not
doing fixes but the Number of Usable SVs is one or more.

*

Note – GPS/UTC Time Offset is the difference between GPS and UTC time standards in
seconds. The UTC time of Day is only valid if the GPS/UTC Offset Valid Flag is indicating
valid.

The TM message is supported under the Set qualifier which allows you to download time
to a GPS receiver that does not have a real-time clock.

Item

# of Char

UNITS

Format

(Value)

Hours

2

Hour

AA

Minutes

2

Min

BB

Seconds

5

Sec

CC.DDD

Date; Day

2

Day

EE

Date; Month

2

Month

FF

Date; Year

4

Year

GGGG

GPS/UTC Time
Offset

2

Sec

HH

Current Fix Source

1

n/a

I

0 = 2D GPS

1 = 3D GPS

2 = 2D DGPS

3 = 3D DGPS

6 = DR

8 = Degraded DR

9 = Unknown

Number of Usable
SVs

2

n/a

JJ

GPS/UTC Offset
Flag

1

n/a

K

(1 = Valid)

(0 = Invalid)

Reserved

5

n/a

LLLLL

Total

28

Advertising