Lassen-SK8 Embedded GPS Module

A-3

Trimble Standard Interface Protocol

A.3

Customizing Receiver Operations

To customize the Lassen-SK8 receiver output for your application:

1.

Set up the receiver using TSIP commands until the receiver operation is as desired

2.

Use command 0x8E-26 to store the settings in non-volatile memory

These settings will control receiver operation whenever the receiver is cold-started, or
when battery back-up is lost. Table A-2 shows all of the commands that can be stored in
SEEPROM.

A.3.1

TAIP Customizing

To customize the receiver for TAIP on either Port 1 or Port 2, use command 0x8E-40
which sets the TAIP default settings. Then use command 0xBC to change port baud
settings and set the language to TAIP.

.If Port 1 is used, TSIP communication will stop so, use TAIP command RT, specifically:

>SRTSAVE_CONFIG<

to store to non-volatile memory instead of 0x8E-26 settings.

A.3.2

NMEA Customizing

To customize the NMEA output on Port 2, use the command 0x7A

A.3.3

Reconfiguring to Factory Default Settings

To reset the receiver configuration to factory default settings, use TSIP command 0x1E
with data byte-F. This will negate all previous 0x8E-26 settings.

I

Caution – Whenever using command 0x8E-26 or 0x1E, wait two seconds before
removing power. This allows the process of writing to non-volatile memory to be
completed.

M

Warning – When changing port settings, record the new settings for future reference.
These settings must be used whenever the receiver is powered up. If the port settings are
lost, use theTPRESET program in the Toolkit disk to return the board to the factory default
settings.