background image

Lassen-SK8 Embedded GPS Module

A-25

Trimble Standard Interface Protocol

Table A-21.

Command Packets 0x35 and 0x55 Data Descriptions

Byte

Parameter
Name

Bit
Position

Default
Bit
Value

Option

Associated
Packet

0

position

0 (LSB)

1

XYZ ECEF Output
0: off
1: on

0x42 or
0x83

1

0

LLA Output
0: off
1: on

0x4A or
0x84

2

0

LLA ALT Output
0: HAE (datum)
1: MSL geoid

0x4A or
0x84
0x8F-17
0x8F-18

3

0

ALT input
0: HAE (datum)
1: MSL geoid

0x2A

4

0

Precision-of-position
output
0: Send single-precision
packet
1: Send double-
precision packet

0x42/4A/8F-
17

0x83/84/8F-
18

0

position

5

0

0: output no Super
Packets
1: output all enabled
Super Packets

0x8F-17,
0x8F-18
0x8F-20

6-7

0

not used

1

velocity

0

1

XYZ ECEF Output
0: off
1: on

0x43

1

0

ENU Output
0: off
1: on

0x56

2-7

0

not used