230 vac operation 2-3, 115 operation 2-3, 230 operation 2-3 – Zebra Technologies 160S User Manual

Page 25: Fuse replacement 2-3, Power connection, Ac voltage selection procedure

Advertising
background image

Temperature: -40° to +158° F (-40° to +70° C)

Relative humidity: 20% to 85% non-condensing

Should it become necessary to ship your printer, remove any ribbon

and paper roll from the supply spools, otherwise damage to the printer

could result. Carefully pack the printer in a suitable container to avoid

damage during transit. Whenever possible, use the original container

and packaging material from the factory. If you use a different con-

tainer, a procedure similar to the original factory packaging should be

followed.

CAUTION: Do not package the printer in a rigid container without util-

izing shock mounts or shock-absorbing packing material. A rigid con-

tainer will allow shock on the outside to be transmitted undamped to

the unit, which may cause damage.

Power Connection

AC Voltage Selection Procedure

The S-Series Printer’s AC voltage may be set for either 115 VAC or

230 VAC operation. To match the printer’s power entry selection to the

available power source, refer to Figure 2.1 and follow the procedure

outlined below:

1. Locate the AC power area at the rear of the printer.
2. Using a small flatblade

screwdriver or similar

tool, move the Voltage

Selection switch to the

115 V or 230 V position

as required. (The initial

position of the switch

depends on how the

printer was ordered.)

Make sure that the ap-

propriate fuse is in place.

See Figure 2.1.

2-2

Zebra S-Series User’s Guide

Figure 2.1 AC Power Area

24