Troubleshooting 8-1 – Zebra Technologies 160S User Manual

Page 75

Advertising
background image

Note: If only one pair of lights is flickering, it indicates that the

adjustment was not successful. Go back to step 1 and start

over.

8. Open the printhead.
9. Pull the media out of the printer until a label is positioned under the

printhead. Move the ribbon back to its normal position.
Note: Be sure that label is positioned between the upper and lower

Media Sensors.

10. Close the printhead.
11. Press the MODE key to print a Media and Sensor Profile and save the

new values (see Figure 7.4.).

12. Perform the Media Calibration procedure in

“Configuration and Cali-

bration.”

7-6

Zebra S-Series User’s Guide

Figure 7.4 Media Sensor Profile Sample Printout

74