AC Power Fuse Replacement

A user-replaceable AC Power Fuse is located just above the Power

ON/OFF Switch (see

Figure 2.1

). For a 115 VAC installation, the re-

placement fuse is a 3AG Fast Blow style rated at 5 Amp/250VAC. For a

230 VAC installation, the fuse is the same style but rated at 3 Amp/250

VAC. Make sure the fuse you use is correct for the voltage source.
Before replacing the fuse, turn the AC Power Switch OFF and unplug

the AC Power Cable.
To replace the fuse, insert the tip of a flatblade screwdriver into the slot

in the end of the Fuse Holder End Cap. Press in slightly on the End

Cap and turn the screwdriver slightly counterclockwise. This will dis-

engage the End Cap from the Fuse Holder and allow you to remove the

fuse. To install a new fuse, reverse the procedure.

115 VAC Operation

1. Confirm that the voltage selector switch is set to 115 V.
2. Attach the supplied power cord to the AC power receptacle located on

the rear of the printer.

3. Connect the opposite end of the power cord to a properly grounded

source of 115 VAC (50 or 60 Hz) power rated for at least 5 Amps.

230 VAC Operation

1. Confirm that the voltage selector switch is set to 230 V.
2. Depending on how the printer was ordered, a power cord may or may

not be provided for 230 VAC operation. If not provided, obtain a cord

set with the proper AC Power plug. The cord may then be connected to

the standard (international) IEC-type 3-prong AC connector provided

on the S-Series Printer. Refer to

“Appendix A”

for more information.