Ascii control codes 5-3, Data terminal ready (dtr) 5-3, Data specifications – Zebra Technologies 160S User Manual

Page 61: Rs-232 serial data port

Advertising
background image

Data Specifications

When communicating via the serial data port (RS-232), the baud rate,

number of data bits, and the parity are user-selectable (see

“Configura-

tion and Calibration”

for acceptable setting combinations). Parity only

applies to data transmitted by the printer, since it ignores the parity of re-
ceived data. The S-Series Printer is fixed at 1 stop bit, so make sure that your
host is also set at 1 stop bit.

When communicating via the parallel port, the previously mentioned

parameters are not considered.

RS-232 Serial Data Port

The connections for the standard interface are made through the DB25S

connector on the rear panel. For all RS-232 input and output signals,the

S-SeriesPrinterfollowsboththeElectronics Industries Association’s (EIA)

RS-232 and the Consultative Committee for International Telegraph and Tele-

phone (CCITT) V.24 standard signal level specifications.

5-2

Zebra S-Series User’s Guide

Pin No.

Description

1

Frame Ground for Cable Shield

2

TXD (Transmit Data) output from the printer

3

RXD (Receive Data) input to the printer

4

RTS (Request To Send) output from the printer

6

DSR (Data Set Ready) input to the printer

7

Signal Ground

20

DTR (Data Terminal Ready) output from the printer

Note:

Pins 5, 8, 10-19, and 21-25 are not used and are unterminated.

Table 5.1 RS-232 Pinouts

60

Advertising
This manual is related to the following products: