Diagnostic test 3-12, Feed key and pause key self test 3-12, Mode key self test 3-12 – Zebra Technologies 160S User Manual

Page 48: Pause key and cancel key self test 3-12, Communications diagnostics 3-12, Feed key and pause key 3-12, Mode key 3-12, Pause key and cancel key 3-12, Feed key test

Advertising
background image

This self test can be used to provide the test printouts required when

making adjustments to the printer’s mechanical assemblies. See the

sample printout in

Figure 3.3

.

FEED Key Self Test

The CANCEL Key Self Test should be performed before this self test.

Information on the “Configuration” printout (CANCEL Key Self Test)

can be used with the results of this self test to determine the best

Darkness setting for a specific media/ribbon combination.
The FEED Key Self Test will print out at various Darkness settings

above and below that of the Darkness value shown on the Configuration

Label. Inspect these labels and determine which one has the best

darkness setting for the application. This value can be entered into the

printer by setting the Darkness during the configuration procedure.

The value printed on that label is added

to (plus) or subtracted from (minus) the

“Darkness” value specified on the Con-

figuration Label. The resulting numeric

value (0 to 30) is the best darkness

value for that specific media/ribbon

combination.
Optionally, the Darkness value can be

programmed into the ZPL II formats

sent to the printer.

Zebra S-Series User’s Guide

3-11

Figure 3.4 FEED Key Test Sample Printout

47

Advertising
This manual is related to the following products: