Calibration 4-4, Configuration mode 4-4, Factory defaults 4-4 – Zebra Technologies 160S User Manual

Page 56: Bank 2

Advertising
background image

Bank 2

These switches can manually override any ZPL II commands that affect

print mode, media mode, and media type. They can also override set-

tings established during the calibration procedure. Reasons why you

might want to use these override switches:

Troubleshooting. By using these switches,

you know beyond a doubt what operating

mode your printer is in.

Lets you use a single ZPL II label format for

many different printers—without worrying if

the format contains a mode command that is

inappropriate for your printer configuration.

Some third-party label design software pack-

ages work better if these switches control the

mode.

If you do not want to override ZPL II or the

calibration settings, disable one or more of the

override options by setting switches 1, 4, and/or

7 to the R (OFF) position and turning the power

ON. With these disabled, the printer will re-

quire ZPL II commands and/or re-calibration to

set print mode, media mode, and/or media type.
To override, set the switches to one of the

modes shown in the table. If you are in the pro-

cess of printing, this change takes effect on the

next label printed. If you change the switches

from active to disabled after printer power-up,

the printer remains in the current mode until a

ZPL II command or re-calibration changes the

mode.

105Se Note: Switch 5 must not be positioned to the right unless the

printer is equipped with the optional black mark sensor.

Zebra S-Series User’s Guide

4-3

Bank 2

Switch

3 2 1

Print Mode

R R L Cutter
R L L Tear-Off
L R L Peel-Off

L L L Rewind
- - R Override is disabled

Switch

6 5 4

Media Mode

R R L Black-mark sensing mode

R L L

Transmissive sensing mode with

non-continuous media (detects a

web/notch)

L L L Transmissive sensing mode with

continuous media

- - R Override is disabled

Switch

8 7

Media Type

R L

Thermal transfer

L L

Direct thermal

- R

Override is disabled

Table 4.2