Power On Self Test

A Power On Self Test (POST) is performed each time the printer is turned

ON. This test checks for proper initialization of various electronic circuits

and establishes starting parameters as those stored in the printer’s memory.

During this test sequence, the front panel lights will turn ON and OFF to

ensure proper operation. At the end of this self test, only the POWER light

will remain lit. If other lights are also lit, refer to the

Troubleshooting Sec-

tion

.

Printer Self Tests

Introduction

These self tests produce sample labels and provide specific information

that helps determine the operating conditions for the printer.
Each self test is enabled by holding in a specific Front Panel key or

combination of keys while turning the Power Switch ON. Keep the key

depressed until the Front Panel Lights turn ON.
When the Power On Self Test is completed, the selected self test auto-

matically starts.
Notes: When performing self tests, all data interface cables connected

to the rear of the printer must be removed.

When canceling a self test before its actual completion, always

turn the printer Power OFF and then back ON to reset the

printer.

When performing these self tests in the Peel-Off Mode, the

operator must remove the labels as they become available.

Unless specifically stated, all tests print in Tear-Off mode in

Tear-Off printers and in Peel-Off Mode for Peel and Rewind

printers.