Lower Transmissive Media Sensor Position Adjustment

To adjust the lower media sensor, follow these steps.

1. Locate the lower media sensor assembly (a spring clip holding a small

printed circuit board) under the rear idler roller.

2. Position the sensor so that the two brass-colored infrared emitters are

under the upper sensor by sliding it in its slot.

3. Gently pull wires out of the printer frame as required. (Wires should

have a little slack.)
Note: If the sensor is being moved inward and a large loop of wire

develops, remove the cover from the electronics side of the

printer and gently pull the wires through. It is important that

the wires be properly clamped so that they are not rubbed by

any belts.

7-4

Zebra S-Series User’s Guide

Figure 7.3 Lower Transmissive Media Sensor Locations