Rt œ read tag 105 – Zebra Technologies R-140 User Manual

Page 115

Advertising
background image

f = Format

Default value: 0 ASCII
Other values: 1 Hexadecimal

r = Retries

Default value: 0
Other values: 1 to 10, number of retries

m = motion

Default value: 0 (Feed label after writing)
Other value: 1 (No Feed after writing, other ZPL may cause

a feed)

s = Reserved

Default value: 0

Example:
This example reads a block from a tag, and prints it on a label:

^XA
^FO20,120^A0N,60^FN1^FS
^FO20,100^A0N,20^FN2^FS
^RT1,7,3,0,5,0,0^FS
^RT2,2,2,0,5,0,0^FS
^XZ

The tag type is set by the front panel or by the ^RS command. The first

^RT command, starting at block 7, reads three blocks of data in ASCII

format. It will retry the command 5 times if necessary. A “void” label will

be generated if the read is unsuccessful after ‘r’ retries. The data read will

go into the ^FN1 location of the format.

106

Zebra R-140 User’s Guide