Cleaning the Cutter Module

(For printers equipped with the optional cutter.)

If labels are not being cut properly or if the cutter jams with labels, turn off

the printer power and unplug the printer. Then, clean the stationary cutter

blade with cleaning solvent. This will remove label adhesive and/or paper

debris. If further cutter cleaning is necessary, or if the cutter continues to

perform unsatisfactorily, contact an authorized service technician.

Lubrication

CAUTION! No lubricating agents of any kind should be used on

this printer! Some commercially available lubricants

will damage the finish and the mechanical parts if

used.

Fuse Replacement

The printer uses a metric-style fuse (5 X 20 mm IEC) rated at F5A, 250V.

The end caps of the fuse must bear the certification mark of a known

international safety organization (see

Figure 36 on page 98

). The printer

comes with two approved fuses: one in the circuit and one in the “spare

fuse” holder.

1. Turn off the printer power and unplug the power cord from the back of

the printer. See

Figure 28

.

2. Using a small-blade screwdriver or similar tool, remove the fuse holder

from the printer.

3. Remove the faulty fuse and install a new fuse of the correct type. Refer

to

Figure 29

. The fuse that goes into the printer first is the one that is

“in-circuit.” If you use the spare fuse, be sure to order a replacement

fuse (fuses can be ordered from your Zebra distributor).