Media and ribbon calibration 21, Me dia and rib bon 21 – Zebra Technologies R-140 User Manual

Page 31

Advertising
background image

10. Press the RIGHT BLACK OVAL key. The front panel display will

show “REMOVE RIBBON CANCEL CONTINUE.”

11. Either remove the ribbon or slide it as far from the printer frame as

possible.

12. Close the printhead, trapping the ribbon in this position.
13. Press the RIGHT BLACK OVAL key. The front panel will show

“CALIBRATING PLEASE WAIT.”

14. When this part of the calibration process is completed, the display will

read “RELOAD ALL CONTINUE.”

15. Open the printhead. Pull the backing material until a label is positioned

between the media sensors.

16. Either load the ribbon or return the ribbon to its proper position.
17. Close the printhead. Press the RIGHT BLACK OVAL key to perform

the next part of the calibration sequence. “MEDIA AND RIBBON

CALIBRATE” displays. The printer is calibrated when the media stops

feeding.

18. Press the SETUP/EXIT key to leave the programming mode. Choose

“permanent” when SAVE CHANGES displays.

22

Zebra R-140 User’s Guide