Zebra R-140 User’s Guide

Press

Display Shows

Action/Explanation

MEDIA AND

RIBBON

CALIBRATE

Media and Ribbon Sensor Sensitivity Press NEXT/SAVE to skip

the calibration procedure and continue with the host port

selection parameters that follow. Press the RIGHT BLACK OVAL

key to start the calibration procedure.
This procedure is used to adjust the sensitivity of the media and

ribbon sensors.
NOTE: The procedure must be followed exactly as presented.

All steps must be performed even if only one of the

sensors requires adjustment.

Media and Ribbon Calibration Procedure

LOAD BACKING

Press the LEFT BLACK OVAL key to cancel the operation, or do

the following:
1) Open the printhead.
2) Remove approximately 8” (203 mm) of labels from the media

roll, enough so that only the backing material is threaded

between the media sensors when the media is loaded.

REMOVE RIBBON

Press the LEFT BLACK OVAL key to cancel the operation or do

the following:
1) Remove the ribbon (sliding it as far to the right as possible will

have the same effect as removing it).
2) Close the printhead.

CALIBRATING

PLEASE WAIT

The printer automatically adjusts the scale (gain) of the signals it

receives from the media and ribbon sensors based on the

specific media and ribbon combination you are using. On the

sensor profile, this essentially corresponds to moving the graph

up or down to optimize the readings for your application.

----

RELOAD ALL

When “RELOAD ALL” is displayed:
1) Open the printhead and pull the media forward until a label is

positioned under the media sensor.
2) Move the ribbon back to its proper position.
3) Close the printhead.

MEDIA AND

RIBBON

CALIBRATE

Now that the scale has changed, the printer performs a

calibration equivalent to pressing the CALIBRATE key. During

this process, the printer checks the readings for the media and

ribbon based on the new scale you have established, determines

the label length, and determines whether you are in direct

thermal or thermal transfer print mode. The process is now

complete! To see the new readings on the new scale, print a

sensor profile.