Statistics

Table 19-4 Hardware Monitor

LABEL DESCRIPTION

Temperature Unit (C) The switch has temperature sensors that are capable of detecting and reporting if the

temperature rises above the threshold. You may choose the temperature unit
(Centigrade or Fahrenheit) in this field. MAC, CPU and PHY refer to the location of
the temperature sensors on the switch printed circuit board.

Current This shows the current temperature in degrees centigrade at this sensor.

Max This field displays the maximum temperature measured at this sensor.

Min This field displays the minimum temperature measured at this sensor.

Threshold This field displays the upper temperature limit at this sensor.

Status This field displays Normal for temperatures below the threshold and Error for those

above.

Fan speed (RPM)

A properly functioning fan is an essential component (along with a sufficiently
ventilated, cool operating environment) in order for the device to stay within the
temperature threshold. Each fan has a sensor that is capable of detecting and
reporting if the fan speed falls below the threshold shown.

Current This field displays this fan's current speed in Revolutions Per Minute (RPM).

Max This field displays this fan's maximum speed measured in Revolutions Per Minute

(RPM).

Min This field displays this fan's minimum speed measured in Revolutions Per Minute

(RPM). "<41" is displayed for speeds too small to measure (under 2000 RPM).

Threshold This field displays the minimum speed at which a normal fan should work.

Status Normal indicates that this fan is functioning above the minimum speed. Error

indicates that this fan is functioning below the minimum speed.

Voltage(V)

The power supply for each voltage has a sensor that is capable of detecting and
reporting if the voltage falls out of the tolerance range.

Current This is the current voltage reading.

Max This field displays the maximum voltage measured at this point.

Min This field displays the minimum voltage measured at this point.

Tolerance A tolerance of plus-minus five percent is the acceptable deviation from the nominal

voltage.

Status Normal indicates that the voltage is within an acceptable operating range at this

point; otherwise Error is displayed.

Poll Interval(s)

The text box displays how often (in seconds) this screen refreshes. You may change
the refresh interval by typing a new number in the text box and then clicking Set
Interval
.

Stop Click

Stop to halt statistic polling.

Advertising