AMI Reference Manual

16

Whenever an “emergency stop” event occurs—such as when the Table Stop
button on the

MILLPWR

operator console is pressed or the system detects a

fault—

MILLPWR

will interrupt the milling machine’s movement and all of the

emergency stop outputs will return to their default state (refer to Table 3).

Figure 7

shows an example of how the AMI emergency stop output might

be used to power down a spindle motor when an emergency stop condition
occurs.

Emergency Stop Output (J17)

The emergency stop outputs are not programmable. Do not wire
external devices that you wish to control (pumps, automatic lubri-
cation systems, etc.) directly into

MILLPWR

’s emergency stop cir-

cuitry.

The J17 connector is commonly used to:

Add other devices to the emergency stop circuitry.

Pin #

Description

1
2
3

Normally closed relay contact
Common relay contact
Normally open relay contact

Table 4 (J17)

Fig. 7