AMI with Spindle Control Reference Manual

29

To enable or disable the motor assembly monitor:

From the Job Setup screen, select Installation Setup and press

ENTER

,

enter the passcode. Select the Diagnostics screen and press

ENTER

again

.

From the Diagnostics screen, highlight Motor Assembly Monitor and
press

ENTER

.

Press either the ENABLED or DISABLED softkey. (If the ENABLED
softkey is selected, the Motor Assembly Monitor display will appear on
the DRO screen.)

Press the

USE

key.

Continue with Diagnostics or press the USE NEW SETTINGS softkey.

Safety feature that will alter the activity of certain program
functions when they are open.

Safety feature that will, under certain conditions, stop pro-
gram functions when the lubrication pump supply reaches a
certain minimum level of oil.

Provides a switch input that can be used in place of the
operator pressing the

GO

key or the remote Stop/Go switch.

Guards
Closed

Oil Not
Low

No Go Key

Advertising