background image

AMI Reference Manual

27

Using the In-Position Relay

Press the

SETUP

key.

From the Installation Setup menu, cursor
down to the AMI Outputs field and press
the

ENTER

key.

Along the bottom of the screen the OFF, ON and PULSED softkeys will
also appear.

If ON is selected, the output will be asserted when the desired X/Y
position is reached and will remain on until the X and Y positions
have moved out of position.

If PULSED is selected, the desired pulse time must be entered in sec-
onds. (Time may be entered to tenths of a second.) The In-Position
relay will remain energized when in position and will be de-energized
when the programmed time has elapsed or program step execution is
completed or aborted.

To save an In-Position configuration, press the USE or the USE NEW
SETTINGS softkey.

Note: Check that the devices you are using are powered on before

running the program.