Ami troubleshooting guide – ACU-RITE MILLPWR Auxiliary User Manual

Page 33

Advertising
background image

AMI Reference Manual

30

Symptom

Probable Cause

Recommended
Corrective Action

No operation or
improper operation

Loose interface cable

No power or incorrect
voltage to AMI

Incorrect voltage setting

Check that the cable is
properly connected to

MILLPWR

and that the

screws are secure.

Check that the AMI
is wired at the correct volt-
age. Also ensure that the
power cables for the
motors are properly daisy-
chained to the

MILLPWR

operator console (refer to
Connecting to a Power
Source
, page 20).

Verify that the voltage
selector switch is set cor-
rectly—at 115 for 115
volt operation; at 220 for
220 volt operation.

Ribbon connector to J14
is loose (European AMIs
only)

Check the connection.
Tighten or reconnect it as
needed.

AMI Troubleshooting Guide

This troubleshooting guide is arranged in three columns—Symptom, Probable
Cause
and Recommended Corrective Action. Begin by locating the symptom
and probable cause that best matches the problem you are experiencing, then fol-
low the directions for each corrective action.

If the suggestions herein do not solve the problem, contact ACU-RITE for repair
and/or replacement procedures.