36

Characteristic

Specification

Operating conditions

0° to 40° C (32° to 104° F)
25% to 85% relative humidity (non-condensing)

Storage conditions

-20° to 60° C (-4° to 140° F)
25% to 95% relative humidity (non-condensing)

115VAC ±10%
230VAC ±10%

47-63Hz

124mA (max.) @ 115VAC
62mA (max.) @ 230VAC

Input requirements:

Voltage

Frequency

Current

Fuse

200mA, 3AG, 250V SLO-BLO @ 115VAC
100mA, 3AG, 250V SLO-BLO @ 230VAC

4 Amps max. @ 230V AC

AMI output relay

contact ratings (J18)

FCC compliance

Part 15 of FCC rules for a class A
computing device

Compatibility

Compatible with ACU-RITE

®

MILLPWR

®

systems software versions 2.1.2 and 3.1.2 or later

Electrical Specifications

The installation location must be able to support the AMI operating and
electrical requirements listed below.

E-Stop Output ratings (J17)

14 Amps max. @ 230V AC

SCI Contact Specifications

(J1, J2 & J5)

0.5 Amps max @ 125V AC