shows a typical wiring diagram for machine guards. As the dia-

gram illustrates, the machine guard switch should be wired to pins 1 and 2.
When the machine guard switches are open, the contacts to those pins will
open, and an Operator Intervention Message (OIM) message will appear on
the

MILLPWR

screen.

Note: If guards are not used then pin 1 and pin 2 of J2 must be

jumpered.

Low Oil is a safety feature that will, under certain conditions, stop program
functions when the lubrication pump supply reaches a certain minimum level
of oil. The normally closed low oil switch should be wired to pins 3 and 4.

When the low oil switch opens:

1) Find Home, Move Table, Single Cycle and all program functions

cannot be initiated.

If the low oil feature activates during these operations:

1) Find Home and Move Table functions will be aborted.
2) Single Cycle and program functions will complete their current

path and then pause.

Note: If a low oil sensor is not used, then pins 3 and 4 must be

jumpered.