Ami with spindle control reference manual, Motor assembly monitor – ACU-RITE MILLPWR Auxiliary User Manual

Page 31

Advertising
background image

AMI with Spindle Control Reference Manual

28

Motor Assembly Monitor

When the motor assembly monitor is enabled, it shows the real-time operat-
ing status of each axis and the AMI on the DRO screen. Use it to verify the
status of all AMI inputs and outputs.

Reports on the AC power status (On or Off); also reports
system failures and emergency stop conditions when they
occur.

Displays the table’s incremental position (its position relative
to incremental zero).

Displays the table’s absolute position (its position relative to
datum).

Reports on each motor’s operating status (On, Off, Not
Present or Fault).

Shows the internal air temperature for each motor.
Temperatures should not exceed 75° C.

Monitors the DC motor current voltage. An "X" after the
value indicates that the voltage inrush bypass circuit is
active. It can also be seen when the E-Stop button is pressed
and then released. The “X” should disappear within 2 - 3
seconds after the system is powered up.

Top Bar

(Power
Status)

INC

ABS

Status

Temp

Current

Advertising
This manual is related to the following products: